• Close
  • EN

DRY COOLER A TAVOLA

DRY COOLER A TAVOLA
Use Mouse Wheel to Zoom In/Out
Price: Richiedi prezzo, risposta entro 1 ora
Item code: MDC-F
Brand: MITA
Unit of measurement: PZ
Quantity:

Description

Dry Cooler Series F

Series MDC-F

Dry coolers are simple and reliable equipment. Their operating principle is based on a sensible heat exchange between air and water where air is drawn by fans through a finned coil, while water (or a mixture of water and glycol) flows through the tubes that make up the coil and cools when the ambient air (cooler) touches its surface. The fins are used to increase the overall heat exchange surface so that the equipment can be as compact and efficient as possible. The water circuit is closed and never in contact with external elements. The only consumption is the electricity to operate the fans. These can be of the AC or EC type while their control is ensured by a controller or a frequency converter that modulates the fan speed based on actual operating conditions. Their performance and return temperature are a consequence of the installation location. The approach temperature is usually around 5°C.

Construction Features

Feature Details
Motors EC directly coupled to the fans
Heat exchange coil Finned in Cu/Al
Control panel Optional, with protections for each fan and differential circuit breaker
Frame and support structure Galvanized sheet metal (thickness 1.5 mm)
Connections Preassembled inlet/outlet for plug and play installation

Technical Specifications

Parameter Value
Length Up to 12.5 m
Versions Single or double row of fans
Coil type Cu/Al
Fin spacing 2.1 - 2.4 - 3.6 mm
Thermal capacity From 20 kW to 2,000 kW* (*?T 15°C @ 25°C ambient temperature)
Fan size Ø 350 - 500 - 630 - 800 - 900 - 1,000 mm
Motor type AC or EC
Number of fans 1 ÷ 16

Options

  • Switch for individual fan
  • Flanged inlet/outlet connections
  • Vertical installation kit with bracket feet
  • Fan support with hinges for opening and cleaning the heat exchanger
  • Vibration damper (elastomeric type) to reduce vibrations

Supply of the cooler is limited to the parts listed above. Building and electrical works, pumps, collectors external to the cooler, valves, hoisting gear, and any scaffolding and labor are therefore excluded. Accessories and/or constructional variants are available on request. MITA Cooling Technologies S.r.l. may carry out constructional improvements without notice. Images are for illustration purposes only.